SUPPRESSING CONDUCTED EMI FROM A DC/DC HIGH POWER CONVERTER BASED ON MIXED-MODE FILTER / 药物分析学报
Journal of Pharmaceutical Analysis ; (6): 113-116,144, 2005.
Article em Zh | WPRIM | ID: wpr-625025
Biblioteca responsável: WPRO
ABSTRACT
Conducted electromagnetic interference (EMI) from a 7.5kVA DC/DC high power converter is investigated to agree with EN class A. Here in some passive methods of suppressing conducted EM Noise, such as mixed-mode (MM) EMI filters, snubbing circuits and other means, are used. Based on measurement, the sources of noise are detected with the characteristics analyzed in detail. The MM EMI filters is valuable means with which low-frequency part and some of the high frequency part of conducted EM Noise can be efficiently reduced. How to lay out the MM filters on both sides of the converter is outlined in detail. In addition, multiple grounding and RDC snubbing circuits are employed to improve the performance in high frequency. The experimental results confirm the methods adopted.