Effectiveness of Serial Measurement of Differential Pressure in Closed Tibial Diaphyseal Fractures in Diagnosing Acute Compartment Syndrome using Whiteside's Technique
Malaysian Orthopaedic Journal ; : 1-4, 2016.
Artigo em Inglês | WPRIM | ID: wpr-626805
ABSTRACT
Acute Compartment Syndrome is a limb-threatening emergency and it occurs most commonly after fractures. The aim of our study is to find out the effectiveness of serial measurement of differential pressure in closed tibial diaphyseal fractures, in diagnosing acute compartment syndrome, using Whiteside’s technique. A total of 52 cases in the age group of 15 to 55 years admitted with closed fractures were studied for serial compartment pressure as well as serial differential pressure. Eight patients had persistent compartment pressure > 40mmHg, out of which only two patients had persistent differential pressure < 30mmHg and these two patients underwent fasciotomy. Thus, by measuring the compartment pressure serially and calculating differential pressure serially, acute compartment syndrome can be diagnosed or ruled out with higher precision, so that unnecessary fasciotomies can be avoided.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Fraturas da Tíbia Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Malaysian Orthopaedic Journal Ano de publicação: 2016 Tipo de documento: Artigo