Your browser doesn't support javascript.
loading
Amniotic membrane transplantation in the treatment of conjunctival rupture, dehiscence and socket contracture after hydroxyapatite orbital implantation / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science ; (12): 2271-2273, 2014.
Artigo em Chinês | WPRIM | ID: wpr-637017
ABSTRACT
AlM To investigate the clinical effect of preserved amniotic membrane transplantation in the treatment to conjunctival rupture, dehiscence and socket contracture after hydroxyapatite ( HA) orbital implantation.

METHODS:

ln 16 cases of conjunctival rupture and socket contracture after HA orbital implantation, conjunctival tension was release by operation and preserved amniotic membrane was transplanted on conjunctival scleral exposure area.

RESULTS:

ln all cases, conjunctiva healing, completely cover the sclera and conjunctiva socket recover ideal depth after operation in 15 cases, 1 case was fail. CONCLUSlON Preserved amniotic membrane transplantation is an effective method to treat conjunctival dehiscence and keeping the ideal conjunctival socket depth after orbital implantation.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: International Eye Science Ano de publicação: 2014 Tipo de documento: Artigo