Your browser doesn't support javascript.
loading
Evaluation of large intracranial aneurysms with cine MRA and 3D contrast-enhanced MRA / 华中科技大学学报(医学)(英德文版)
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 95-8, 106, 2004.
Artigo em Inglês | WPRIM | ID: wpr-640969
ABSTRACT
The value of combined application of both ECG-gated cine MRA and 3D-CEMRA in the detection of large intracranial aneurysms was evaluated and the findings were compared with those of conventional MRA and DSA. Twenty-four patients with 26 large intracranial aneurysms underwent MRI and DSA. All these aneurysms, diameter from 15 to 39 mm, were located at internal cerebral artery (n=12), vertebral artery (n=3), basilar artery (n=4), anterior cerebral artery (n=2), middle cerebral artery (n=2), anterior communicate artery (n=2) and posterior communicate artery (n=1). Thirteen cases of hematoma or cavernoma were studied as control group. All patients were examined on GE 1.5T MR system. ECG-gated cine MRA was performed with 2D multi-phase fast gradient-recalled echo sequence in a single section. All the images were analyzed with signal intensity VS time curve for differentiating intraaneurysmal blood flow from static tissue. The results were analyzed by statistic "t" test. 3D-CEMRA was performed with spoiled gradient-recalled echo and one dose of Gd-DTPA. All data was processed with multi-plannar reformat (MPR) and tomography for the demonstration of aneurysms in detail. All 26 aneurysms were demonstrated successfully by combined application of both cine MRA and 3D-CEMRA. Compared to DSA and conventional 3D-MOTSA, its sensitivity and specificity figures were both 100%. Cine MRA could differentiate the blood flow from the static tissue. The intensity VS time curves of intraaneurysmal blood flow offered fluctuating form and average signal change between systole and diastole period was about 89.8 +/- 37.4; However, under the control group, intraaneurysmal thrombus or cerebral hemorrhage or cavernomas had no significant signal change and the curves offered steady form with the average signal change being about 8.2 +/- 6.3. There was statistically significant difference between the intraaneurysmal blood flow and static tissue (P=0.025, <0.05). 3D-CEMRA was very useful in demonstrating the aneurysmal size, intraaneurysmal thrombus formation, neck and the detailed relationship of the aneurysm to the surrounding structures. It was concluded that the combined application of both cine MRA and 3D-CEMRA might be a valuable clinical tool for the detection of large intracranial aneurysms.
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Processamento de Imagem Assistida por Computador / Aumento da Imagem / Angiografia Digital / Aneurisma Intracraniano / Angiografia por Ressonância Magnética / Imagem Cinética por Ressonância Magnética / Meios de Contraste / Estudo de Avaliação / Imageamento Tridimensional Idioma: Inglês Revista: Journal of Huazhong University of Science and Technology (Medical Sciences) Ano de publicação: 2004 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Processamento de Imagem Assistida por Computador / Aumento da Imagem / Angiografia Digital / Aneurisma Intracraniano / Angiografia por Ressonância Magnética / Imagem Cinética por Ressonância Magnética / Meios de Contraste / Estudo de Avaliação / Imageamento Tridimensional Idioma: Inglês Revista: Journal of Huazhong University of Science and Technology (Medical Sciences) Ano de publicação: 2004 Tipo de documento: Artigo