Analysis on tear film after LASIK by femtosecond laser with Oculus corneal topography / 国际眼科杂志(Guoji Yanke Zazhi)
International Eye Science
;
(12): 1116-1118, 2014.
Artigo
em Chinês
| WPRIM
| ID: wpr-641852
ABSTRACT
AIM:
To observe the changes of tear film on the patients after laser in situ keratomileusis ( LASIK) with corneal flap created by femtosecond laser with Oculus corneal topography.METHODS:
Totally 120 myopic patients (240 eyes) were collected who underwent femtosecond laser surgery LASIK from August to September 2013, and these patients can be followed up for 3mo. Tear break-up time ( BUT) and tear meniscus height ( TMH ) with Oculus corneal topography were recorded preoperatively and postoperatively at 1wk;1, 2 and 3mo.RESULTS:
Oculus BUT there existed obvious differences (P=0. 012, 0. 000, 0. 023 0. 05 ) existed in 3mo compared with the preoperative level. TMHthere existed obvious differences (P=0. 025, 0. 019, 0. 0260. 05 ) existed in 3mo compared with the preoperative level.CONCLUSION:
Femtosecond laser surgery affects the stability of the tear film at a certain time and a certain extent. The mechanism related to many factors. It is temporary and lighted.