A Covered Nitinol Stent Fracture in a Patient with a Malignant Esophageal Stricture: A Case Report
Journal of the Korean Radiological Society ; : 321-324, 2008.
Artigo em Coreano | WPRIM | ID: wpr-64378
ABSTRACT
Self-expanding metallic stent insertion has been widely applied for the palliative treatment of malignant esophageal strictures. Although it is known as an easy, safe, and effective procedure, complications are well known and include things such as stent migration and esophageal stent occlusion caused by tumor ingrowth. However, metallic stent fractures have been rarely reported in the esophagus, especially for nitinol stents. We report a case of a stent fracture associated with migration in a patient with a malignant esophageal stricture near the gastroesophageal junction. It is highly probable that the stent fracture was due to chemical erosion of the stent caused by gastric juice.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Cuidados Paliativos / Stents / Constrição Patológica / Ligas / Estenose Esofágica / Junção Esofagogástrica / Esôfago / Suco Gástrico Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Radiological Society Ano de publicação: 2008 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Cuidados Paliativos / Stents / Constrição Patológica / Ligas / Estenose Esofágica / Junção Esofagogástrica / Esôfago / Suco Gástrico Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Radiological Society Ano de publicação: 2008 Tipo de documento: Artigo