Polished Tapered Femoral Stem Displacement during the Closed Reduction of a Redislocated CementedBipolar Hemiarthroplasty of the Hip: A Case Report / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association ; : 659-663, 2008.
Artigo em Coreano | WPRIM | ID: wpr-644494
ABSTRACT
Redislocation of bipolar hemiarthroplasty is not a simple complication. When redislocation of bipolar hemiarthroplasty occurs, open reduction must be considered. Displacement of the polished tapered femoral stem could occur through the unwanted traction force during the reduction of the dislocated cemented hip arthroplasty as a complication. We experienced displacement of the polished tapered femoral stem during closed reduction of a redislocated cemented bipolar hemiarthroplasty. We suggest that preoperative analysis for the cause and status of the dislocation is essential and open reduction should be considered if closed reduction is not thought to be suitable for a polished femoral stem.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Artroplastia / Tração / Luxações Articulares / Deslocamento Psicológico / Hemiartroplastia / Quadril Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2008 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Artroplastia / Tração / Luxações Articulares / Deslocamento Psicológico / Hemiartroplastia / Quadril Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2008 Tipo de documento: Artigo