Varus Positined Femoral Stem in Cementless Total Hip Arthroplasty / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association
;
: 586-592, 2007.
Artigo
em Coreano
| WPRIM
| ID: wpr-644950
ABSTRACT
PURPOSE:
This study examined the effect of a varus positioned femoral stem after cementless proximal fitting total hip arthroplasty. MATERIALS ANDMETHODS:
A total of 144 hips in 136 patients who underwent cementless total hip arthroplasty, were followed-up. Twenty-one varus positioned hips were compared with 123 neutral positioned hips. The clinical results were analyzed according to the level of thigh pain and the Harris Hip score. The radiological outcome was assessed according to osteolysis, loosening and stem failure.RESULTS:
In the varus positioned hips, thigh pain was present in 1 hip, and the average Harris Hip Score was 96 points. None of the implants showed radiological evidence of loosening or impending failure. Localized osteolysis was identified in 1 hip, non-progressive radiolucencies in 2 hips, and cortical hypertrophy in 1 hip. In the neutral positioned hips, thigh pain was present in 6 hips, and the average Harris Hip Score was 97 points. Localized osteolysis was identified in 8 hips, non-progressive radiolucencies in 7 hips, cortical hypertrophy in 9 hips.CONCLUSION:
Patients with varus alignment of the stem did not present poorer clinical outcomes than those with neutral alignment of the stem.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Osteólise
/
Coxa da Perna
/
Artroplastia de Quadril
/
Quadril
/
Hipertrofia
Tipo de estudo:
Estudo prognóstico
Limite:
Humanos
Idioma:
Coreano
Revista:
The Journal of the Korean Orthopaedic Association
Ano de publicação:
2007
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS