It is well known that suprasternal notch is at the midpoint between the carina and vocal cords. We evaluated the distance from the endotracheal tube tip on the suprasternal notch to upper incisor using flexible lightwand. 97 male(height 155~187 cm) and 100 female(height 144~167 cm) patients of undergoing elective surgery were included in the study. After adjust the lamp of the tracheal lightwand at the tube tip, endotracheal tube was placed under anesthesia at the suprasternal notch using the light glow. The distance between upper incisor to suprasternal notch was recorded. The average distance from upper incisor to suprasternal notch was 20.0(+/-1.0)cm in males, 17.9(+/-0.7)cm in females. We demonstrated that the placing the tracheal tube at the suprasternal notch using lightwand was rapid and reliable method for identification of proper tube positioning. We have shown that securing endotracheal tube at upper incisor 23 cm in males and 21 cm in females are positioned distally.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Traqueia / Prega Vocal / Incisivo / Anestesia Limite: Adulto / Feminino / Humanos / Masculino Idioma: Coreano Revista: Korean Journal of Anesthesiology Ano de publicação: 1995 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Traqueia / Prega Vocal / Incisivo / Anestesia Limite: Adulto / Feminino / Humanos / Masculino Idioma: Coreano Revista: Korean Journal of Anesthesiology Ano de publicação: 1995 Tipo de documento: Artigo