ABSTRACT
Insertion of a pulmonary artery catheter for the measurement of pulmonary artery pressures and cardiac output has been widely used for the management of patients undergoing open heart surgery. Complications of pulmonary artery catheter insertion include cardiac arrhythmia, thromboembolism, tricuspid valve injury, intracardiac knotting, pulmonary artery rupture. We experienced a case of catheter-related complication which was caused by suturing pulmonary artery catheter during right atrial bleeding control during open heart surgery. The catheter was attached to the right atrial wall by nylon suture and successfully removed by operation without significant complication.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Arritmias Cardíacas / Artéria Pulmonar / Ruptura / Suturas / Cirurgia Torácica / Tromboembolia / Valva Tricúspide / Débito Cardíaco / Catéteres / Coração Limite: Humanos Idioma: Coreano Revista: The Korean Journal of Critical Care Medicine Ano de publicação: 1998 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Arritmias Cardíacas / Artéria Pulmonar / Ruptura / Suturas / Cirurgia Torácica / Tromboembolia / Valva Tricúspide / Débito Cardíaco / Catéteres / Coração Limite: Humanos Idioma: Coreano Revista: The Korean Journal of Critical Care Medicine Ano de publicação: 1998 Tipo de documento: Artigo