Thrombosis in the Left Ventricle after Implantable Cardioverter-Defibrillator Implantation: A Rare Cause of Systemic Thromboembolism / 대한구급학회지
The Korean Journal of Critical Care Medicine
;
: 27-31, 2014.
Artigo
em Inglês
| WPRIM
| ID: wpr-652370
ABSTRACT
This report describes a case of systemic thromboembolism caused by left ventricular (LV) thrombosis that developed after placement of an implantable cardioverter-defibrillator (ICD). A 27-year-old male patient was diagnosed with idiopathic dilated cardiomyopathy and ventricular tachycardia, and underwent ICD implantation for the primary prevention of sudden cardiac death. Two weeks after ICD implantation, the patient experienced renal infarction. Transthoracic echocardiography revealed a mobile thrombus at the LV apex, and automated function imaging demonstrated deteriorated LV function after ICD implantation. The RV was not placed by ICD and the mechanical force which was occurred by ICD that led to induced dyssynchronous motion of the LV apex may have resulted in a systemic thromboembolism.