Your browser doesn't support javascript.
loading
Cementless Total Hip Arthroplasty Using Dual Offset Titanium Tapered Stem: At Least 7-Year Follow-Up / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association ; : 419-427, 2017.
Artigo em Coreano | WPRIM | ID: wpr-655102
ABSTRACT

PURPOSE:

The purpose of current study is to evaluate the midterm results of cementless primary total hip arthroplasty (THA) using a dual offset titanium tapered stem. MATERIALS AND

METHODS:

A retrospective analysis of 102 cases (84 patients), with a minimum of 7-year clinical follow-up, was performed. All of the cases consisted of patients who underwent primary cementless THA, using a dual offset titanium tapered stem in The Catholic University of Korea, Bucheon St. Mary's Hospital between July 2004 and May 2009. Clinical results were analyzed via the Harris hip score, level of thigh pain, squeaking around hip joint, and complication rate. Radiologic results were examined with stability and location of inserted prosthesis, hypertrophy of femoral cortex, and osteolysis.

RESULTS:

Out of the 102 cases (84 patients; 47 males and 37 females), with the mean age of 55.9 years (range, 27–79 years) and mean follow-up period of 99.2 months (range, 84–132 months). The mean Harris hip score was 53.8 preoperatively (range, 26–75) and improved to 93.5 postoperatively (range, 74–100) (p=0.000). All of the cases gained stable bony fixation on the final follow-up, including 2 cases of intra-operative proximal femur fracture. Calcar remodeling was observed in 94 cases, however, they were irrelevant with stem stability. Cortical hypertrophy of femur was seen in 12 cases and thigh pain in 4 cases; nonetheless, they were not relevant (p=0.067). There was 1 case of squeaking sound during joint movement. Hip dislocation occurred in 1 case early after the procedure, but the event was due to excessive anteversion of the acetabular cup, in which a revisional replacement procedure of the acetabular cup was conducted. No sign of ceramic breakage was observed. There were 2 cases of heterotrophic ossification.

CONCLUSION:

Results from a 7-year follow-up of cementless THA using dual offset titanium tapered stem were encouraging in both clinical and radiologic evaluations.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Osteólise / Próteses e Implantes / Coxa da Perna / Titânio / Cerâmica / Estudos Retrospectivos / Seguimentos / Artroplastia de Quadril / Fêmur / Quadril Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos / Masculino País/Região como assunto: Ásia Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Osteólise / Próteses e Implantes / Coxa da Perna / Titânio / Cerâmica / Estudos Retrospectivos / Seguimentos / Artroplastia de Quadril / Fêmur / Quadril Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos / Masculino País/Região como assunto: Ásia Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2017 Tipo de documento: Artigo