Your browser doesn't support javascript.
loading
Surgical Outcomes after Olecranon Plating with Retrograde Coronoid Process Screw Fixation through the Plate Hole in the Bifocal Fracture of the Proximal Ulna / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association ; : 403-410, 2016.
Artigo em Coreano | WPRIM | ID: wpr-655514
ABSTRACT

PURPOSE:

Bifocal fracture of the proximal ulna is a fracture of the olecranon accompanied by fracture of the coronoid process. The purpose of the current study was to analyze the clinical results of the author's technique in bifocal fracture of the proximal ulna. MATERIALS AND

METHODS:

Fifteen patients (10 men, 5 women) treated at CHA Bundang Medical Center from April 2006 to October 2014 were analyzed retrospectively. All patients underwent internal fixation using a locking compression plate (LCP) with retrograde screw fixation of the coronoid process through a screw hole of the plate. Mean age of the patients was 42.6 years and the mean follow-up period was 18.6 months. Comminuted coronoid fractures with hard to screw fixation, complex injuries combined with open damage, and complete ligament rupture were excluded. Fracture union and articular congruity were examined on the follow-up radiographs. Range of motion, disability of the arm, shoulder and hand (DASH) score, and Mayo elbow performance score were evaluated for functional analysis.

RESULTS:

Fracture union was achieved and articular step off was less than 2 mm in all patients on the follow-up radiographs. The mean value of modified Mayo elbow score was 92.14 (80–100) and DASH score was 7.11 at last follow-up. The mean range of motion of elbow was 128o. There was one case of small heterotopic ossification as a radiographic complication which had no functional deficit.

CONCLUSION:

Internal fixation of bifocal multifragmentary articular fractures of the proximal ulna with anatomically contoured LCP olecranon plate and retrograde long screws could be a recommendable surgical procedure. This study showed that the precontoured plate with retrograde coronoid process screw fixation can produce good clinical and radiographic outcomes in bifocal fractures of the proximal ulna. We recommend this procedure in this type of fracture.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Braço / Ruptura / Ombro / Ulna / Estudos Retrospectivos / Seguimentos / Amplitude de Movimento Articular / Ossificação Heterotópica / Cotovelo / Olécrano Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos / Masculino Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Braço / Ruptura / Ombro / Ulna / Estudos Retrospectivos / Seguimentos / Amplitude de Movimento Articular / Ossificação Heterotópica / Cotovelo / Olécrano Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Humanos / Masculino Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2016 Tipo de documento: Artigo