Your browser doesn't support javascript.
loading
Tube Erosion with Scleral Melting after Ahmed Valve Implantation Using a Synthetic Dural Substitute
Article em Ko | WPRIM | ID: wpr-65558
Biblioteca responsável: WPRO
ABSTRACT
PURPOSE: The objective of this case report was to present tube erosion of Ahmed valve implantation using a synthetic dura substitute (Neuro-Patch®, B. Braun, Boulogne, France). CASE SUMMARY: Tube erosion was caused by dissolution of the conjunctiva and partial-thickness scleral tunnel in 5 patients who received Ahmed valve implantation using a synthetic dura substitute for glaucoma treatment 2 to 4 months after the operation. Furthermore, the patients required re-operation for preventing secondary complications such as endophthalmitis. CONCLUSIONS: This case series using a synthetic dura substitute in Ahmed valve implantation demonstrated the risk of tube erosion with scleral tunnel melting and following secondary complications even with a partial-thickness scleral tunnel method.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Glaucoma / Endoftalmite / Túnica Conjuntiva / Congelamento / Métodos Limite: Humans Idioma: Ko Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2017 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Glaucoma / Endoftalmite / Túnica Conjuntiva / Congelamento / Métodos Limite: Humans Idioma: Ko Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2017 Tipo de documento: Article