Your browser doesn't support javascript.
loading
Comparison of domestic infantile type video intubationscope and stethoscope in positioning of double-lumen endobronchial tube / 中国内镜杂志
China Journal of Endoscopy ; (12): 6-10, 2017.
Artigo em Chinês | WPRIM | ID: wpr-658270
ABSTRACT
Objective To compare the effect of the domestic infantile type video intubationscope (VIS) and stethoscope in positioning of double-lumen endobronchial tube (DLT). Methods 100 cases of patients underwent elective thoracic surgery requiring single lung ventilation were randomly divided into two groups domestic infantile type video intubationscope group (group V) and stethoscope group (group S), with 50 cases in each. After intubating with a DLT, the positions of DLT were judged and adjusted by VIS (group V) and stethoscope (group S) respectively, and then reviewed by fiberoptic bronchoscopy (FOB), the positioning time and accuracy were recorded. Results Comparing with the group S, the positioning time of DLT was significantly shorter and the total positioning accuracy of DLT was significantly higher in group V (P < 0.05). Conclusion It is easy and quickly, high accuracy with domestic infantile type video intubationscope in positioning of DLT, which is worthy of clinical popularization and application.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Journal of Endoscopy Ano de publicação: 2017 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Journal of Endoscopy Ano de publicação: 2017 Tipo de documento: Artigo