Evaluation of the quality and efficiency of SRT plans for intracranial tumors using Fixed and Iris collimators of CyberKnife / 中华放射肿瘤学杂志
Chinese Journal of Radiation Oncology
; (6): 1292-1297, 2017.
Article
em Zh
| WPRIM
| ID: wpr-667555
Biblioteca responsável:
WPRO
ABSTRACT
Objective To discuss and evaluate the dosimetric characteristics of different plans implementing stereotactic radiotherapy(SRT)for intracranial tumors using Fixed and Iris collimators of CyberKnife VSI.Methods Twenty patients with intracranial tumors were selected and divided into group A with a small target volume(≤30 cm3)and group B with a large target volume(≥30 cm3). There were 10 patients in each group,and the prescribed dose to the target was 21 Gy in 3 fractions. For each patient, two treatment plans were designed using Fixed and Iris collimators. By analyzing the dosimetric parameters such as conformity index(CI),homogeneity index(HI), gradient index(GI), gradient score index(GSI), and organs at risk (OAR),the quality and efficiency of the plans were evaluated in order to discuss the beam characteristics for two sets of collimators. The difference was analyzed with the paired t-test. Results The mean time of Iris plan for delivering was significantly less than that of Fixed plan(group A:P=0.001;group B:P=0.000). In group B,the peripheral dose(20% and 10% of the prescribed dose)volumes of Fixed plan were significantly less than those of Iris plan(P=0.001 and 0.009). For OAR,D minof the visual pathway and D meanor D minof the eyeball in group B were significantly different between Fixed and Iris plans(all P<0.05), while in group A, only D minof the optic chiasm was significantly different between the two plans(P=0.043). For the other parameters of targets,there were no significant differences between Fixed and Iris plans in both groups(all P>0.05). Conclusions Apart from less treatment time in the Iris plan, there are no significant dosimetric differences between the two collimator plans of CyberKnife VSI in treating small intracranial tumor. For the large and complex tumor,although Iris plan meets the requirement for OAR dose constraints,its low-dose volumes are larger than those of Fixed plan. Further studies of the dosimetric characteristics in CyberKnife should be done.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Radiation Oncology
Ano de publicação:
2017
Tipo de documento:
Article