Your browser doesn't support javascript.
loading
Study on Quality Standard for Lixue Pills / 中国药师
China Pharmacist ; (12): 1824-1826, 2015.
Artigo em Chinês | WPRIM | ID: wpr-670079
ABSTRACT

Objective:

To establish the quality standard for Lixue pills.

Methods:

TLC was used to identify the active ingredients, and HPLC was used to determine the content of hesperidin in the preparation. The analysis was performed on a WondaSil C18 column (250 mm ×4.6 mm,5 μm) with the mobile phase of acetonitrile-water-phosphoric acid(20800.1)at a flow rate of 1.0 ml·min-1. The column temperature was maintained at 40℃. The detection wavelength was set at 284 nm.

Results:

The specific spots of the active ingredients were presented clearly by TLC without any interference from the negative control. The linearity of hesperidin was good with-in the range of 16. 560-82. 800 μg·ml-1(r=0. 999 8), and the average recovery was 98. 8%(RSD=1. 1%, n=6).

Conclusion:

The method is accurate and reliable, which can be used for the quality control of Lixue pills.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Pharmacist Ano de publicação: 2015 Tipo de documento: Artigo

Similares