Evaluation of 4 dentin adhesives in vivo / 实用口腔医学杂志
Journal of Practical Stomatology
; (6)2000.
Article
em Zh
| WPRIM
| ID: wpr-670642
Biblioteca responsável:
WPRO
ABSTRACT
Objetives: To evaluate the microtensile bond strengths o f four dentin adhesives (Single Bond, Bond-1, Prime&Bond NT and One-Step) i n vivo.Methods: Before extraction the superficial occlu sal dentin of 19 molars (because of severe periodontitis) in 17 volunteers was exposed by diamond bur of a high-speed hand-piece copious air-water spray under local anesthesia, the crown was bonded with one of the above adhesives a ccording to the manufacturers' instructions. The teeth were then extracted and kept in normal saline for 24 h under 37 ℃,sectioned to obtain two or three bar -shaped specimens, which were then shaped to an hour-glass form. The specimens were stressed until rupture of the bond. The mean bond strength of the adhesive s was measured and compared using student test. Rusults: M ean microtensile bond strength (MPa) of Single Bond,Bond-1,One-Step and Prime & Bond NT to the tooth surface was 26.18?3.67,30.08?3.15,29.91?3.51,29.70?3 .03 respectively (P
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Journal of Practical Stomatology
Ano de publicação:
2000
Tipo de documento:
Article