The evaluation of peri-implant bone defects with bioelectrical impedance in canine / 实用口腔医学杂志
Journal of Practical Stomatology
;
(6): 77-80, 2015.
Artigo
em Chinês
| WPRIM
| ID: wpr-671943
ABSTRACT
Objective:
To measure the bioelectrical impedance around the dental implants with bone defects.Methods:
Bilateral maxillar second premolar were extracted in 6 native mongrel dogs,implants were placed immediately with or without bone defect of corresponding alveolar bene.Impedance value(IV)between the implant and contralateral mouth corner was measured by LCR TEST-ER.IVs were compared and analyzed by SPSS.Results:
IVs of bone defect group were bigger than that of control group(P <0.05), in largger defect group were smaller than that in smaller group(P <0.05).Conclusion:
Bioelectrical impedance can be used as an evaluation of peri-implant bone defects and the size of bone defect.