Evaluation of CT-guided percutaneous transthoracic biopsy in the diagnosis of mediastinal masses / 介入放射学杂志
Journal of Interventional Radiology
; (12)2006.
Article
em Zh
| WPRIM
| ID: wpr-683488
Biblioteca responsável:
WPRO
ABSTRACT
Objective To evaluate the clinical application and safety of CT-guided pereutaneous transthoracic biopsy in the diagnosis of mediastinal masses.Methods Thirty three cases were undertaken CT- guided percutaneous transthoraeie biopsy with automatic biopsy gun and then the sampling specimens were undergone histological examination.The accuracy of puncture,diagnostic correctness and complications were analyzed.Results The operations were performed successfully in all 33 cases(100%),the definite pathologic diagnosis were made in 28 out of 33 cases(85%)and no complications occurred.Conclusion As for midiastinal masses,CT-guided percutaneous transthoracic biopsy is a feasible,successful,efficient interventional diagnostic method with high accuracy in localization,puncture,diagnosis and few complications, which should he recommended in clinical use more widely.(J Intervent Radiol,2007,16:852-854)
Texto completo:
1
Índice:
WPRIM
Tipo de estudo:
Diagnostic_studies
Idioma:
Zh
Revista:
Journal of Interventional Radiology
Ano de publicação:
2006
Tipo de documento:
Article