Your browser doesn't support javascript.
loading
Echocardiography-guided percutaneous closure of patent ductus arteriosus without arterial access: Feasibility and safety for a new strategy / 中南大学学报(医学版)
Journal of Central South University(Medical Sciences) ; (12): 1000-1006, 2018.
Artigo em Chinês | WPRIM | ID: wpr-693859
ABSTRACT

Objective:

To evaluate the feasibility and safety of device closure of patent ductus arteriosus (PDA)using only venous access under echocardiography guidance alone.

Methods:

A total of 102 consecutive pediatric patients underwent transcatheter PDA closure without arterial access,under the guidance of only echocardiography.The patients were followed up by clinical examination,electrocardiogram,and echocardiogram at 1,3,6 12,and 24 months.

Results:

Transvenous PDA closure under echocardiographic guidance was successful in 99 (97.1%)patients.There were no acute procedural complications or severe adverse events.The duration ranged from 10 to 65 minutes (median,21 minutes).Immediate complete closure of PDA was achieved in 87 patients (87.9%),and 100% of the patients were completely closed after 24 h.There were no severe adverse events in the period of 1-24 months (median,12 months) follow up.

Conclusion:

Transvenous PDA closure without fluoroscopy avoids radiation exposure,contrast agent usage and potential arterial complications.It can be used as an alternative procedure,especially for children.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Guia de Prática Clínica Idioma: Chinês Revista: Journal of Central South University(Medical Sciences) Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Guia de Prática Clínica Idioma: Chinês Revista: Journal of Central South University(Medical Sciences) Ano de publicação: 2018 Tipo de documento: Artigo