Your browser doesn't support javascript.
loading
Clinical application of MdaccAutoPlan in the planning of nasopharyngeal carcinoma with intensity modulated radiotherapy / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 285-290, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708056
ABSTRACT
Objective To compare the MdaccAutoPlan (MDAP)software with Manual planning in intensity modulated radiotherapy (IMRT) planning for nasopharyngeal carcinoma (NPC) patients.Methods A total of 20 newly diagnosed NPC patients were enrolled and their IMRT plans were designed with MDAP software and manually,respectively with identical field angle,optimization parameters and other planning requirements.Dosimetric differences and planning efficiency were compared for these two planning method.Results The PGTV Dgs%,PGTV D PTV1 Dgs%,PTV1 D PTV2 D98%,PTV2 D of plans generated from MDAP were reduced by 2.5%,0.3%,0.1%,0.5%,0.6%,1.0%,respectively,compared with those in plans generated manually.The D2% of the PGTV,PTV1,PTV2 in MDAP plans were increased by 1.7%,1.5%,0.6% compared with those in manual plans,respectively.There were significant differences observed in the PGTV D9s%,PGTV D2% and PTV2 Dg8% between these two planning method (t =5.519,6.701,0.937,P < 0.05).The D50% of right parotidand left parotid,the D and D of the spinal cord in MDAP plans were reduced significantly by 24.8%,27.7%,11.4%,14.0%,respectively,compared with those in manual plans (t =5.447,5.375,6.786,3.810,P < 0.05).The dose of both lens increased significantly by 65.0% and 19.3%,respectively,in MDAP plans compared with Manual plans (t =9.863,3.440,P < 0.05).There was no significant dosimetric difference observed in opticnerve,opticchiasm and brainstem between these two planning method.The dose distribution of post neck in MDAP plans were better than those in manual plans.The dose-volume histogram curves of planning target volume,brainstem and spial cord in the manul plans were higher than those in the MDAP plans.The labor time of MDAP planning was reduced by 54.4% compared with Manual planning,while computer working time was increased by 34.4% with MDAP planning compared with Manual planning.Conclusions MDAP planning is clinically valualbe in its applicaion for a NPC IMRT planning with a better sparing for OARs,a decreased planning time and improvement on planning efficiency compared with manual planning.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Guia de Prática Clínica Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Guia de Prática Clínica Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2018 Tipo de documento: Artigo