Patient positioning, port placements setting and robot cart docking in pediatric robot-assisted laparoscopic upper urinary tract operation / 中华泌尿外科杂志
Chinese Journal of Urology ; (12): 601-605, 2018.
Artigo em Chinês | WPRIM | ID: wpr-709568
ABSTRACT
Objective To summarize the experience of patient positing,port placements setting and robot cart docking in pediatric robot-assisted laparoscopic upper urinary tract operations.Methods From March 2017 to December 2017,140 robot-assisted laparoscopic upper urinary tract procedures were performed in our institution,including 110 cases of pyeloplasty,15 upper pole heminephroureterectomy,12 simple nephrectomy and 3 adrenalectomy.There were 103 males and 37 females with a range age from 1 month to 18 years.The assistant surgeon was adjacent to the instrument nurse,and patients were placed in a supine position with 60°-80° inclination and keep the legs low to the body.Room setup and patient positioning were similar to the traditional laparoscopic surgery.Semi-hidden incision technique was used in 140 patientsthe camera port was placed umbilicus,two additional arm ports (one 5 mm and one 8 mm) were placed under direct vision,the 8 mm arm port was placed on the line of a Pfannenstiel incision and the 5 mm arm port was placed below the Xiphoid along the midline.Finally,a 3 or 5 mm assistant port was placed approximately 3 cm lateral to the inferior arm port,the line of a Pfannenstiel incision.Results The average time was (11.5 ± 3.2) min (10.5-16.5 min) from skin incision to robot cart docking completed.All surgeries were successfully completed without open conversion.One patient required an additional assist port for severe adhesion after the previously open surgery,there was no injury to other viscera.Average operative time was (146.9 ± 48.7)min (78-259 min) and average post-operative hospitalization time was (5.7 ± 1.4) d(4-10 d),respectively.There was no visual scar on abdominal 6 weeks postoperatively,and all parents made comments about their satisfaction with the cosmetic appearance.All operations got complete success at a mean follow up of 6 (1-9) months.Conclusions A good room setup,patient positioning and the semi-hidden incision technique port placements are maintaining the safety of the patient,avoiding compression injuries,allowing maximum mobility of the robotic arms,and facilitating a smooth and efficient surgery,and improving post-operative recovery.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Urology Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Urology Ano de publicação: 2018 Tipo de documento: Artigo