Your browser doesn't support javascript.
loading
Application of X-ray assisted nasal catheter extractor to nose biliary oronasal conversion / 中华消化内镜杂志
Chinese Journal of Digestive Endoscopy ; (12): 167-170, 2018.
Artigo em Chinês | WPRIM | ID: wpr-711500
ABSTRACT
Objective To investigate the effect of X-ray assisted nasal catheter extractor on nose biliary oronasal conversion. Methods A total of 892 patients,receiving endoscopic nasal biliary drainage in Affiliated Zhongshan Hospital of Dalian University from January 2014 to December 2015, were randomly divided into experiment group and control group. X-ray assisted nasal catheter extractor was used in the experiment group,and guide wire was used in the control group. The mean extracting number and operation time, the total success rate, one-time success rate, response to stimulation and the incidence of complications were compared between the two groups. Results There were 457 cases in the experiment group. The mean extracting number was 1.08±0.32,the mean operation time was 1.07±0.29 min,the total success rate was 100.00%(457/457)and one-time success rate was 93.65%(428/457). The stimulation degree score was 1.27±0.50 with 348 cases of mild response,96 cases of moderate response and 13 cases of severe response. The rate of adverse reaction was 15.54%(71/457)with 50 cases of nausea, 18 cases of vomiting and 3 cases of mucosal bleeding. There were 435 cases in control group. The mean extracting number was 1.68±0.61,the mean operation time was 1.75±0.53 min, the total success rate was 75.63%(329/435)and one-time success rate was 38.16%(166/435). The stimulation degree score was 1.59 ±0.62 with 210 cases of mild response,194 cases of moderate response and 31 cases of severe response. The rate of adverse reaction was 35.86%(156/435)with 87 cases of nausea,36 cases of vomiting,27 cases of mucosal bleeding,and 6 cases of nasal duct prolapsed for vomiting. There were significant differences in the mean extracting number, mean operation time, stimulation degree score and the adverse reaction rate between the two groups(all P<0.001). The total success rate and one-time success rate in the experiment group were higher than those in the control group(all P<0.001).Conclusion X-ray assisted nasal catheter extractor can improve the success rate of operation,shorten the operation time,reduce the stimulation degree and the rate of adverse reactions in nose biliary oronasal conversion.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Digestive Endoscopy Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Digestive Endoscopy Ano de publicação: 2018 Tipo de documento: Artigo