Your browser doesn't support javascript.
loading
Spyglass visual impression and Spybite targeted biopsies for diagnosis of biliary strictures of unknown reasons: a meta-analysis / 中华消化内镜杂志
Chinese Journal of Digestive Endoscopy ; (12): 583-589, 2018.
Artigo em Chinês | WPRIM | ID: wpr-711545
ABSTRACT
Objective To study the diagnostic value of Spyglass visual impression and Spybite targeted biopsies for biliary strictures of unknown reasons. Methods Several Chinese and English databases were electronically searched for studies on biliary strictures diagnosed with Spyglass visual impression and Spybite targeted biopsies compared with golden standard ( pathological biopsy, autopsy and long-term clinical follow-up) . The methodological quality of the included studies was assessed according to QUADAS-2 items. The software Meta-DiSc ( version 1. 4 ) was used to conduct pooling on sensitivity, specificity, positive likelihood radio, negative likelihood radio and diagnostic odds ratio ( DOR ) . Heterogeneity test was performed and the summary receiver operating characteristic curve ( SROC ) was drawn for area under the curve ( AUC) . Results A total of 12 studies met the inclusion criteria, involving 532 patients who received Spyglass visual impression and 525 who received Spybite targeted biopsies. The combined specificity, sensitivity, positive likelihood ratio, negative likelihood ratio and DOR were 0. 90 (95%CI0. 85-0. 94), 0. 89 (95%CI0. 85-0. 93), 7. 12 (95%CI 4. 36-11. 64), 0. 12 (95%CI0. 07-0. 22)and 82. 40 (95%CI33. 73-201. 28)for Spyglass visual impression, and 0. 98 (95%CI0. 96-1. 00), 0. 66 (95%CI0. 60-0. 71), 13. 29 (95%CI6. 92-25. 53), 0. 37 (95%CI0. 28-0. 47)and 51. 05 (95%CI23. 58-110. 53) for Spybite targeted biopsies, respectively. The AUC on the SROC of Spyglass visual impression and Spybite targeted biopsies were 0. 9574 and 0. 9398, respectively. Conclusion Spyglass visual impression is useful for detecting malignant lesion, whereas Spybite targeted biopsies is better at confirming malignant diagnosis, which indicates combination of the two methods have good diagnostic value for indeterminate biliary strictures, but their negative results are not perfect in excluding biliary cancer.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Revisões Sistemáticas Avaliadas Idioma: Chinês Revista: Chinese Journal of Digestive Endoscopy Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Revisões Sistemáticas Avaliadas Idioma: Chinês Revista: Chinese Journal of Digestive Endoscopy Ano de publicação: 2018 Tipo de documento: Artigo