Your browser doesn't support javascript.
loading
Two Small Intravenous Catheters for High-Rate Contrast Medium Injection for Computed Tomography in Patients Lacking Superficial Veins to Accommodate a Large Catheter
Korean Journal of Radiology ; : 489-497, 2018.
Artigo em Inglês | WPRIM | ID: wpr-715442
ABSTRACT

OBJECTIVE:

To prospectively investigate the feasibility of using 2 small intravenous catheters for high-rate computed tomography (CT) contrast injection in patients lacking superficial veins capable of accommodating ≤ 20-gauge catheters. MATERIALS AND

METHODS:

Sixty-eight consecutive eligible adults referred for dynamic liver CT were enrolled; 58 had previously undergone liver CT, including 8 that experienced extravasation. Two 22- or 24-gauge catheters were placed in all patients after 2–5 venipunctures, and 2 mL/kg of contrast agent (370 mg I/mL) was split-administered through both catheters to achieve total flow rate of 4 mL/s. Patients' experience and examination success rate, defined as uneventful scans completed at 4 mL/s or at < 4 mL/s achieving standard image quality in all phases, were analyzed. Quantitative hepatic signal-to-noise and hepatic vascular contrast-to-noise ratios (CNRs) were compared with 30 control examinations scanned at 4 mL/s using an 18-gauge catheter.

RESULTS:

One case each of extravasation and severe injection pain caused the examination to be aborted. Success rate was 88.2% (60/68; 54 patients scanned at 4 mL/s, 6 at 3.5–3.9 mL/s). Fifty-five of 58 patients (94.8%) that had past CT regarded the venipuncture as more tolerable than (n = 36) or similar to (n = 19) past experiences; 45 of 58 patients (77.6%) found contrast injection less painful than (n = 35) or similar to (n = 10) past experiences. When compared with control examinations, signal-to-noise ratio was similar in all phases (p ≥ 0.502), but the hepatic arterial CNR in arterial phase was slightly inferior (p ≤ 0.047).

CONCLUSION:

Using 2 small intravenous catheters can effectively achieve high-rate CT contrast injection in patients lacking adequate superficial veins.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Veias / Estudos Prospectivos / Satisfação do Paciente / Flebotomia / Meios de Contraste / Catéteres / Tomografia Computadorizada Multidetectores / Razão Sinal-Ruído / Fígado Tipo de estudo: Estudo observacional Limite: Adulto / Humanos Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Garantia da Qualidade dos Cuidados de Saúde / Veias / Estudos Prospectivos / Satisfação do Paciente / Flebotomia / Meios de Contraste / Catéteres / Tomografia Computadorizada Multidetectores / Razão Sinal-Ruído / Fígado Tipo de estudo: Estudo observacional Limite: Adulto / Humanos Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2018 Tipo de documento: Artigo