Cuff Technique for Small-Diameter Vascular Grafts in the Systemic Arterial Circulation of the Rat
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 423-426, 2018.
Artigo em Inglês | WPRIM | ID: wpr-718907
ABSTRACT
This study determined the feasibility of the cuff technique for small-caliber vascular grafts in a rat model. A graft was implanted with the cuff technique or suture technique in a 1-cm segment of the abdominal aorta in 12 rats. The mean aortic clamp time was 29 minutes with the cuff technique and 44 minutes with the suture technique; the cuff technique was significantly shorter. Abdominal angiography at 1 week after implantation showed no significant stenosis in 9 rats, focal stenosis of the mid-portion of the graft in 1 rat with each technique, and total occlusion of the graft in 1 rat with the suture technique. We have successfully used the cuff technique for anastomosis for small-caliber vascular grafts in an animal model.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aorta Abdominal / Angiografia / Técnicas de Sutura / Constrição Patológica / Transplantes / Modelos Animais Limite: Animais Idioma: Inglês Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aorta Abdominal / Angiografia / Técnicas de Sutura / Constrição Patológica / Transplantes / Modelos Animais Limite: Animais Idioma: Inglês Revista: The Korean Journal of Thoracic and Cardiovascular Surgery Ano de publicação: 2018 Tipo de documento: Artigo