Your browser doesn't support javascript.
loading
Captured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty / 신경중재치료의학
Neurointervention ; : 52-57, 2013.
Artigo em Inglês | WPRIM | ID: wpr-730218
ABSTRACT
The authors present a case in which macro-embolus from the ruptured atheromatous plaque developed during carotid artery stenting (CAS). A 63-year-old man who had suffered a left middle cerebral artery territory infarction had significant proximal left internal carotid artery stenosis required CAS procedure. Immediate after stent deployment, the patient showed abrupt neurological deterioration with 12 x 3 mm sized macro-embolus which was caught by the embolus protection device (EPD). Retrieval of the macro-embolus was performed safely and the patient recovered to pre-procedure status. Macro-embolus can be resulted during the CAS. The EPD can capture the macro-embolus and safe removal is technically feasible.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Artérias Carótidas / Stents / Estenose das Carótidas / Angioplastia / Artéria Cerebral Média / Embolia / Dispositivos de Proteção Embólica / Infarto Limite: Humanos Idioma: Inglês Revista: Neurointervention Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Artérias Carótidas / Stents / Estenose das Carótidas / Angioplastia / Artéria Cerebral Média / Embolia / Dispositivos de Proteção Embólica / Infarto Limite: Humanos Idioma: Inglês Revista: Neurointervention Ano de publicação: 2013 Tipo de documento: Artigo