Reference Values for the Ambulatory Blood Pressure in Normotensive Korean Young Men
Korean Circulation Journal
;
: 458-462, 1992.
Artigo
em Coreano
| WPRIM
| ID: wpr-73050
ABSTRACT
BACKGROUND:
To obtain reference values for the ambulatory blood pressure, 30 normotensive Korean young males, aged 22-28 years(mean age 25 years) were investigated.METHODS:
The ambulatory blood pressure was recorded with SpaceLabs Model 90207 monitor over 24 hours at 20 minutes intervals during day-time(6 am-10pm) and at 30 minutes intervals during night-time (10 pm-6 am).RESULTS:
The ambulatory blood pressure of the 30 subjects averaged 119/74mmHg over 24 hours, 122/78 mmHg during day-time and 112/68 mmHg during night-time. The upper limit of normal ambulatory blood pressure was suggested as the value of mean+/-2SD which revealed 131/84mmHg for 24 hours, 134/90 mmHg for day-time and 126/80 mmHg for night-time.CONCLUSION:
Reference values for the ambulatory blood pressure, in normotensive Korean young men, were obtained by SpaceLab model 90207 monitor.