Validation of the Japanese Version of the STOP-Bang Test for the Risk Assessment of Obstructive Sleep Apnea Syndrome / 日本プライマリ・ケア連合学会誌
An Official Journal of the Japan Primary Care Association
;
: 26-31, 2019.
Artigo
em Japonês
| WPRIM
| ID: wpr-738350
ABSTRACT
Objective:
The objective of this study was to validate the Japanese version of the STOP-Bang test for risk assessment of obstructive sleep apnea syndrome (OSAS).Methods:
We retrospectively evaluated inpatients who underwent nocturnal pulse oximetry for OSAS screening at the internal medical wards.Results:
One hundred and forty-four subjects were included the study, and 57 subjects who had a 3% oxygen desaturation index ≥10/hr underwent polysomnography. Seventeen and 29 subjects were diagnosed with moderate and severe OSAS, respectively. According to the receiver operating characteristic (ROC) curve analysis, the STOP-Bang test had a higher diagnostic value using a cutoff of 30 kg/m2 for BMI than using a cutoff of 35 kg/m2. A STOP-Bang score of 3 or greater had a sensitivity of 95.7% and specificity of 42.9% for detecting moderate-to-severe OSAS.Conclusion:
The STOP-Bang test is a simple and useful tool for the risk assessment of OSAS.
Buscar no Google
Índice:
WPRIM (Pacífico Ocidental)
Tipo de estudo:
Estudo de etiologia
/
Estudo prognóstico
/
Fatores de risco
Idioma:
Japonês
Revista:
An Official Journal of the Japan Primary Care Association
Ano de publicação:
2019
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS