Transscleral Cyclopexy Using Partial-Thickness Scleral Flap for Repairing Cyclodialysis Cleft: a Case Report
Journal of the Korean Ophthalmological Society
; : 393-398, 2019.
Article
em Ko
| WPRIM
| ID: wpr-738615
Biblioteca responsável:
WPRO
ABSTRACT
PURPOSE: To report a case of a cyclodialysis cleft that was successfully managed with gonioscopically guided transscleral cyclopexy using partial-thickness scleral flap. CASE SUMMARY: A 44-year-old man complaining of blurred vision in the left eye after blunt trauma was referred to our hospital. The intraocular pressure (IOP) was 4 mmHg and the visual acuity was counting finger. Gonioscopy examination revealed cyclodialysis cleft from 3 to 6 o'clock and fundus examination revealed macular folds. After the failure of conservative medical therapy and laser photocoagulation, gonioscopically guided transscleral cyclopexy using partial-thickness scleral flap was performed. Four months later, the IOP was 18 mmHg, the visual acuity was 0.8, and fundus examination showed the disappearance of the macular folds. CONCLUSIONS: Transscleral cyclopexy using partial-thickness scleral flap is a safe and effective method to treat hypotony maculopathy due to cyclodialysis and to minimize pupil distortion.