Your browser doesn't support javascript.
loading
Transscleral Cyclopexy Using Partial-Thickness Scleral Flap for Repairing Cyclodialysis Cleft: a Case Report
Article em Ko | WPRIM | ID: wpr-738615
Biblioteca responsável: WPRO
ABSTRACT
PURPOSE: To report a case of a cyclodialysis cleft that was successfully managed with gonioscopically guided transscleral cyclopexy using partial-thickness scleral flap. CASE SUMMARY: A 44-year-old man complaining of blurred vision in the left eye after blunt trauma was referred to our hospital. The intraocular pressure (IOP) was 4 mmHg and the visual acuity was counting finger. Gonioscopy examination revealed cyclodialysis cleft from 3 to 6 o'clock and fundus examination revealed macular folds. After the failure of conservative medical therapy and laser photocoagulation, gonioscopically guided transscleral cyclopexy using partial-thickness scleral flap was performed. Four months later, the IOP was 18 mmHg, the visual acuity was 0.8, and fundus examination showed the disappearance of the macular folds. CONCLUSIONS: Transscleral cyclopexy using partial-thickness scleral flap is a safe and effective method to treat hypotony maculopathy due to cyclodialysis and to minimize pupil distortion.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Acuidade Visual / Pupila / Dedos / Gonioscopia / Pressão Intraocular / Fotocoagulação / Métodos Limite: Adult / Humans Idioma: Ko Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2019 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Acuidade Visual / Pupila / Dedos / Gonioscopia / Pressão Intraocular / Fotocoagulação / Métodos Limite: Adult / Humans Idioma: Ko Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2019 Tipo de documento: Article