A Removed Chestnut Thorn after Corneal Incision
Journal of the Korean Ophthalmological Society ; : 496-500, 2019.
Artigo em Coreano | WPRIM | ID: wpr-738624
ABSTRACT

PURPOSE:

To report the surgical technique to remove a chestnut thorn through a corneal incision. CASE

SUMMARY:

A 54-year-old female visited our clinic complaining of a sudden foreign body sensation and conjunctival injection in her left eye after picking chestnuts 4 days prior to her visit. Visual acuity of both eyes was 1.0 and the intraocular pressures were within normal limits. Slit lamp examination revealed that a chestnut thorn had deeply penetrated the left corneal stroma and a small number of inflammatory cells were observed in the anterior chamber. There was no corneal defect stained with fluorescein and the Seidel test was negative. A corneal foreign body comprised of a chestnut thorn and its remnants was diagnosed and emergency surgery was performed. A partial corneal incision was made along the foreign body and the exposed foreign body was easily and completely removed. The patient was treated with topical antibiotics after surgery and no complication was observed during a follow-up period of 3 months.

CONCLUSIONS:

In the case of a corneal foreign body comprised of a chestnut thorn, the foreign body with its remnants were easily removed by performing a partial corneal incision.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Sensação / Acuidade Visual / Corpos Estranhos no Olho / Seguimentos / Substância Própria / Fluoresceína / Emergências / Lesões da Córnea / Lâmpada de Fenda / Corpos Estranhos Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Feminino / Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2019 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Sensação / Acuidade Visual / Corpos Estranhos no Olho / Seguimentos / Substância Própria / Fluoresceína / Emergências / Lesões da Córnea / Lâmpada de Fenda / Corpos Estranhos Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Feminino / Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2019 Tipo de documento: Artigo