Spurious Elevation of Glucose Concentration during Administration of High Dose of Ascorbic Acid in a Patient with Type 2 Diabetes on Hemodialysis
Yonsei Medical Journal ; : 1289-1292, 2013.
Artigo em Inglês | WPRIM | ID: wpr-74269
ABSTRACT
We describe herein a case of life-threatening hypoglycemia due to spurious elevation of glucose concentration during the administration of ascorbic acid in a type 2 diabetic patient. A 31-year-old female was admitted for proliferative diabetic retinopathy treatment and prescribed high dose ascorbic acid. During hospitalization, she suddenly lost her consciousness and her glucose concentration was 291 mg/dL, measured using self-monitoring blood glucose (SMBG) device, while venous blood glucose concentration was 12 mg/dL. After intravenous injection of 50% glucose solution, the patient became alert. We reasoned that glucose measurement by SMBG device was interfered by ascorbic acid. Physicians should be aware of this interference; high dose ascorbic acid may cause spurious elevation of glucose concentration when measuring with SMBG devices.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Ácido Ascórbico / Glicemia / Automonitorização da Glicemia / Diálise Renal / Diabetes Mellitus Tipo 2 / Hipoglicemia Limite: Adulto / Feminino / Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Ácido Ascórbico / Glicemia / Automonitorização da Glicemia / Diálise Renal / Diabetes Mellitus Tipo 2 / Hipoglicemia Limite: Adulto / Feminino / Humanos Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo