Use of silicon T-tube in laryngotracheal reconstruction / 临床耳鼻咽喉头颈外科杂志
Journal of Clinical Otorhinolaryngology Head and Neck Surgery
;
(24): 882-883, 2011.
Artigo
em Chinês
| WPRIM
| ID: wpr-748057
ABSTRACT
OBJECTIVE@#To discuss the function and operative method of silicon T tube in laryngotracheal reconstruction.@*METHOD@#Two hundred and ninety-seven patients of laryngotracheal stenosis were operated with laryngotracheal reconstruction in our department. All of patients were tracheostomy dependent before reconstruction and were placed a silicon T-tube stenting for 3 to 6 months after reconstruction.@*RESULT@#Two hundred and eighty-nine patients (97.3%) were successfully decannulated with good airway patency and effective phonation. They were followed up from 1 to 10 years, and no recurrence was found.@*CONCLUSION@#Silicon T-tube is an effective and safe stent for laryngotracheal reconstruction. Paying attention to some application details may avoid the complication and obtain a satisfactory effect.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Silício
/
Cirurgia Geral
/
Estenose Traqueal
/
Laringoestenose
/
Procedimentos de Cirurgia Plástica
/
Métodos
Limite:
Adolescente
/
Adulto
/
Criança
/
Feminino
/
Humanos
/
Masculino
Idioma:
Chinês
Revista:
Journal of Clinical Otorhinolaryngology Head and Neck Surgery
Ano de publicação:
2011
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS