Comparing the effect of low-temperature plasma radiofrequency and traditional method in tonsillectomy / 临床耳鼻咽喉头颈外科杂志
Journal of Clinical Otorhinolaryngology Head and Neck Surgery
;
(24): 325-326, 2012.
Artigo
em Chinês
| WPRIM
| ID: wpr-749403
ABSTRACT
OBJECTIVE@#To compare and analyse the efficiency of the low-temperature plasma radiofrequency and the traditional method in tonsillectomy.@*METHOD@#Sixty-four patients with chronic tonsillitis were randomly divided into group A (39 cases) and group B (25 cases). Patients in the group A were treated with traditional method tonsillectomy while patients in the group B were treated with low-temperature plasma radio frequency tonsillectomy. Analysed differences in operation time, blood loss, and postoperative pain as well as the incidence of postoperative between two groups.@*RESULT@#There were significant differences in operative time, blood loss, and postoperative pain (P 0.05).@*CONCLUSION@#Low-temperature plasma radiofrequency tonsillectomy is a safer method and has many superiorities including shorter operative time, less blood loss, quicker recovery of postoperative pain compared with traditional tonsillectomy.