Your browser doesn't support javascript.
loading
Stainless steel wire in a figure-of-eight for repair of distal femoral physeal fractures in ten cats: a case report
Journal of Veterinary Science ; : e71-2019.
Artigo em Inglês | WPRIM | ID: wpr-758950
ABSTRACT
Ten cats were treated for distal femoral Salter-Harris fractures types I and II using a stainless steel wire in a figure-of-eight configuration. Healing was uneventful in 8 of the cats. Early fixation failure occurred in one cat, which required revisional surgery. In one cat, lameness recurred after fracture healing, which was related to breakage of the wire. The lameness was resolved after removing the wire. At the long-term follow-up, 1 out of 6 cats was lame. This report indicates that the figure-of-eight stainless steel wire technique is an alternative method for the repair of distal femoral Salter-Harris fractures types I and II in cats.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aço Inoxidável / Fios Ortopédicos / Seguimentos / Consolidação da Fratura / Fêmur / Métodos Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Journal of Veterinary Science Ano de publicação: 2019 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Aço Inoxidável / Fios Ortopédicos / Seguimentos / Consolidação da Fratura / Fêmur / Métodos Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Journal of Veterinary Science Ano de publicação: 2019 Tipo de documento: Artigo