Your browser doesn't support javascript.
loading
Treatment of Exposed Hydroxyapatite Orbital Implants Wrapped with a Synthetic Dura Substitute
Korean Journal of Ophthalmology ; : 267-271, 2019.
Artigo em Inglês | WPRIM | ID: wpr-760025
ABSTRACT

PURPOSE:

To describe cases of exposed hydroxyapatite (HA) implants wrapped with the synthetic dura substitute Neuro-Patch treated via simple Neuro-Patch removal.

METHODS:

The medical records of seven patients who experienced exposure of their HA implant were reviewed. All patients had been enucleated and implanted with HA wrapped with Neuro-Patch. For treatment, Neuro-Patch was removed to the greatest extent possible. After applying local anesthesia with lidocaine, blunt dissection was performed to separate the conjunctiva and Neuro-Patch via the site of exposure. Pressure was applied to the remaining Neuro-Patch with forceps and removed with scissors.

RESULTS:

Neuro-Patch was visible at the area of exposure in all patients. No surgery beyond initial Neuro-Patch removal was necessary in six of the seven patients. In five cases, the exposed area began to heal rapidly after Neuro-patch removal without primary closure of the defect. In one case, the Neuro-Patch material and all necrotic tissue was removed aggressively due to inflammation around the orbital implant. Lastly, an infection was noted in one case, prompting complete removal of the Neuro-Patch–wrapped HA implant.

CONCLUSIONS:

Wrapping material may hinder implant vascularization. Exposure of HA in wrapped implants can be successfully treated by a simple removal procedure if detected and managed early.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Órbita / Instrumentos Cirúrgicos / Prontuários Médicos / Durapatita / Túnica Conjuntiva / Implantes Orbitários / Inflamação / Anestesia Local / Lidocaína Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Inglês Revista: Korean Journal of Ophthalmology Ano de publicação: 2019 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Órbita / Instrumentos Cirúrgicos / Prontuários Médicos / Durapatita / Túnica Conjuntiva / Implantes Orbitários / Inflamação / Anestesia Local / Lidocaína Tipo de estudo: Estudo diagnóstico Limite: Humanos Idioma: Inglês Revista: Korean Journal of Ophthalmology Ano de publicação: 2019 Tipo de documento: Artigo