Annual Report on the External Quality Assessment Scheme for Urinalysis and Faecal Occult Blood Testing in Korea (2015)
Journal of Laboratory Medicine and Quality Assurance
;
: 120-128, 2016.
Artigo
em Coreano
| WPRIM
| ID: wpr-76003
ABSTRACT
In Korea, external quality assessment trials for urinalysis and faecal occult blood (FOB) were performed for 1,250 participants. Urine chemistry and FOB tests were evaluated three times, whereas urine sediment by photography was evaluated twice. Urine chemistry tests consisted those for pH, protein, glucose, ketone, bilirubin, blood, urobilinogen, nitrite, leukocyte, and specific gravity. The results of the urine chemistry and specific gravity tests showed accuracy rates >95%. In the FOB quality test, all reagents showed false-positive results. These reagents showed positive results in stool specimens containing >11 ng/mL haemoglobin. In the FOB quantitative test, the results were significantly different, based on the instrument used for the measurements. The average accuracy rate of urine sediments was 90.8%, whereas those for renal epithelial cells and cholesterol crystals were 83%.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Gravidade Específica
/
Urobilinogênio
/
Bilirrubina
/
Fotografação
/
Química
/
Colesterol
/
Urinálise
/
Células Epiteliais
/
Glucose
/
Concentração de Íons de Hidrogênio
País/Região como assunto:
Ásia
Idioma:
Coreano
Revista:
Journal of Laboratory Medicine and Quality Assurance
Ano de publicação:
2016
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS