Your browser doesn't support javascript.
loading
Correction of Single Thoracic Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Comparison of Stainless Steel to Titanium Alloy Instruments / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association ; : 141-149, 2019.
Artigo em Coreano | WPRIM | ID: wpr-770047
ABSTRACT

PURPOSE:

To compare the results of two different instruments made of stainless steel and titanium alloy for correction of single thoracic adolescent idiopathic scoliosis (AIS) using pedicle screw instrumentation. MATERIALS AND

METHODS:

A total of 141 patients with single thoracic AIS treated with pedicle screw instrumentation and selective thoracic fusion were retrospectively reviewed after a follow-up of 2 years. The patients had a main thoracic curve of 40° to 75° and were divided into two groups based on instrument materials; S group (stainless steel, n=90) and T group (titanium alloy, n=51). The diameter of the stainless steel rod used was 7.0 mm while that of the titanium alloy rod was 6.35 mm or 6.0 mm. Standing long-cassette radiographic measurements including various coronal and sagittal parameters for the preoperative, early postoperative and 2-year postoperative follow-up were analyzed. There were no significant differences in the preoperative curve characteristics between the two groups.

RESULTS:

In the S group, the preoperative main thoracic curve of 51.3°±8.4° was improved to 19.0°±7.6° (63.1% correction) and the lumbar curve of 32.3°±8.4° spontaneously decreased to 12.7°±8.2° (62.9% correction) at 2 years postoperatively. In the T group, the preoperative main thoracic curve of 49.5°±8.4° and the lumbar curve of 30.3°±8.9° was improved to 18.8°±7.4° (62.2% correction) and 11.3°±5.4° (63.3% correction), respectively. The corrections of coronal curves were not statistically different between the two groups (p>0.05). The thoracic kyphosis was changed from 16.8°±8.5° to 24.3°±6.1° in the S group and from 19.6°±11.2° to 26.6°±8.5° in the T group. There were no significant differences in the changes of sagittal curves, coronal and sagittal balances at the 2-year follow-up and the number of fused segments and used screws between the two groups (p>0.05).

CONCLUSION:

When conducting surgery for single thoracic AIS using pedicles screw instrumentation, two different instruments made of stainless steel and titanium alloy showed similar corrections for coronal and sagittal curves.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Escoliose / Aço Inoxidável / Aço / Titânio / Estudos Retrospectivos / Seguimentos / Ligas / Parafusos Pediculares / Cifose Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Adolescente / Humanos Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2019 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Escoliose / Aço Inoxidável / Aço / Titânio / Estudos Retrospectivos / Seguimentos / Ligas / Parafusos Pediculares / Cifose Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Adolescente / Humanos Idioma: Coreano Revista: The Journal of the Korean Orthopaedic Association Ano de publicação: 2019 Tipo de documento: Artigo