Clinical and Radiologic Results Comparing the Periarticular Proximal Humerus Locking Plate and Polarus Nail for Displaced Proximal Humerus Fractures
Journal of the Korean Shoulder and Elbow Society ; : 208-216, 2017.
Artigo em Inglês | WPRIM | ID: wpr-770821
ABSTRACT

BACKGROUND:

This study compared the clinical and radiological outcomes of the single calcar screw plate and Polarus nail techniques for the treatment of the proximal humerus fractures.

METHODS:

Seventy-two patients diagnosed with displaced proximal humerus fracture were enrolled for the study. Of these, 50 patients underwent the locking plate surgery with a single calcar screw (plate group), whereas 22 patients underwent the Polarus nail surgery (nail group). The plate group was further divided into plate 1 group (with medial support), and plate 2 group (without medial support). The radiological and functional results of both groups were compared to the nail group.

RESULTS:

The α angle 1 year after surgery was significantly different between plate 1 and plate 2, and plate 2 and nail groups (p=0.041, p=0.043, respectively). The ratio that does not satisfy the reference value of γ angle was 2.8% in plate 1, 7.1% in plate 2 and 22.7% in nail group (p=0.007); there was a significant difference between plate 1 and nail group, and plate 2 and nail group (p=0.014, p=0.033, respectively).

CONCLUSIONS:

No significant differences were observed in the clinical results between locking plate and Polarus nail. However, in the plate 2 group and nail group, the rate of failure to maintain reduction during the 1-year period after surgery was statistically and significantly higher than the plate 1 group (level of evidence level IV, case series, treatment study).