Your browser doesn't support javascript.
loading
Extracorporeal Membrane Oxygenation Cannula Malposition in the Azygos Vein in a Neonate with Right-Sided Congenital Diaphragmatic Hernia / 대한구급학회지
The Korean Journal of Critical Care Medicine ; : 152-155, 2016.
Artigo em Inglês | WPRIM | ID: wpr-770931
ABSTRACT
Malposition of the extracorporeal membrane oxygenation (ECMO) venous cannula in the azygos vein is not frequently reported. We hereby present such a case, which occurred in a neonate with right-sided congenital diaphragmatic hernia. Despite ECMO application, neither adequate flow nor sufficient oxygenation was achieved. On the cross-table lateral chest radiograph, the cannula tip was identified posterior to the heart silhouette, which implied malposition of the cannula in the azygos vein. After repositioning the cannula, the target flow and oxygenation were successfully achieved. When sufficient venous flow is not achieved, as in our case, clinicians should be alerted so they can identify the cannula tip location on lateral chest radiograph and confirm whether malposition in the azygos vein is the cause of the ineffective ECMO.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Veia Ázigos / Radiografia Torácica / Oxigenação por Membrana Extracorpórea / Catéteres / Hérnias Diafragmáticas Congênitas / Coração Limite: Humanos / Recém-Nascido Idioma: Inglês Revista: The Korean Journal of Critical Care Medicine Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Veia Ázigos / Radiografia Torácica / Oxigenação por Membrana Extracorpórea / Catéteres / Hérnias Diafragmáticas Congênitas / Coração Limite: Humanos / Recém-Nascido Idioma: Inglês Revista: The Korean Journal of Critical Care Medicine Ano de publicação: 2016 Tipo de documento: Artigo