Your browser doesn't support javascript.
loading
Accuracy of different image registration methods in image-guided adaptive brachytherapy for cervical cancer / 南方医科大学学报
Journal of Southern Medical University ; (12): 1344-1348, 2018.
Artigo em Chinês | WPRIM | ID: wpr-771470
ABSTRACT
OBJECTIVE@#To compare the accuracy of different methods for image registration in image-guided adaptive brachytherapy (IGABT) for cervical cancer.@*METHODS@#The last treatment planning CT images (CT1) and the first treatment planning CT images (CT2) were acquired from 15 patients with cervical cancer and registered with different match image qualities (retained/removed catheter source in images) and different match regions [target only (S Group)/ interested organ structure (M Group)/body (L Group)] in Velocity3.2 software. The dice similarity coefficient (DSC) between the clinical target volumes (CTV) of the CT1 and CT2 images (CTVCT1 and CTVCT2, respectively) and between the organs-at-risk (OAR) of the two imaging datasets (OARCT1 and OARCT2, respectively) were used to evaluate the image registration accuracy.@*RESULTS@#The auto-segmentation volume of the catheter source using Velocity software based on the CT threshold was the closest to the actual volume within the CT value range of 1700-1800 HU. In the retained group, the DSC for the OARs of was better than or equal to that of the removed group, and the DSC value of the rectum was significantly improved ( < 0.05). For comparison of different match regions, the high-risk target volume (HRCTV) and the low-risk target volume (IRCTV) had the best precision for registration of the target area, which was significantly greater than that of M group and L group ( < 0.05). The M group had better registration accuracy of the target area and the best accuracy for the OARs. The DSC values of the bladder and rectum were significantly better than those of the other two groups ( < 0.05).@*CONCLUSIONS@#The CT value range of 1700-1800 HU is optimal for automatic image segmentation using Velocity software. Automatic segmentation and shielding the volume of the catheter source can improve the image quality. We recommend the use of interested organ structures regions for image registration in image-guided adaptive brachytherapy for cervical cancer.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Radioterapia / Dosagem Radioterapêutica / Padrões de Referência / Planejamento da Radioterapia Assistida por Computador / Software / Braquiterapia / Diagnóstico por Imagem / Tomografia Computadorizada por Raios X / Neoplasias do Colo do Útero / Órgãos em Risco Tipo de estudo: Estudo diagnóstico / Estudo de etiologia Limite: Feminino / Humanos Idioma: Chinês Revista: Journal of Southern Medical University Ano de publicação: 2018 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Radioterapia / Dosagem Radioterapêutica / Padrões de Referência / Planejamento da Radioterapia Assistida por Computador / Software / Braquiterapia / Diagnóstico por Imagem / Tomografia Computadorizada por Raios X / Neoplasias do Colo do Útero / Órgãos em Risco Tipo de estudo: Estudo diagnóstico / Estudo de etiologia Limite: Feminino / Humanos Idioma: Chinês Revista: Journal of Southern Medical University Ano de publicação: 2018 Tipo de documento: Artigo