Your browser doesn't support javascript.
loading
Determination of Urinary Iodine Concentration by Inductively Coupled Plasma-mass Spectrometry in Thyroid Cancer Patients on Low-iodine Diet / 대한진단검사의학회지
Article em Ko | WPRIM | ID: wpr-77842
Biblioteca responsável: WPRO
ABSTRACT
BACKGROUND: Thyroid cancer patients should be on low-iodine diet (LID) before radioactive iodine therapy (RAIT) to maximize the effect of RAIT. Urinary iodine excretion is the most accurate marker of very recent dietary iodine intake. We developed and evaluated the analytical performance of inductively coupled plasma-mass spectrometry (ICP-MS) to determine urinary iodine concentration. METHODS: We evaluated the linearity, precision, accuracy, and lower limit of quantification (LLOQ) of an ICP-MS method (Agilent 7500ce) to determine urinary iodine concentration in accordance with the Food and Drug Administration (FDA) guidelines for bioanalytical method validation. This method was used to determine and compare the iodine concentration in random urine samples of 120 thyroid cancer patients on LID for 1 week and 80 healthy adults on normal diet. RESULTS: Our ICP-MS method showed good linearity (1.0-1,913 microgram/L; R2>0.999). Both intra-day and inter-day precision CV were within 20% for the LLOQ (1 microgram/L) and within 15% for the other concentrations. Accuracy was 110-120% for the LLOQ and 95-115% for the other concentrations. The median concentration of iodine in random urine samples from thyroid cancer patients on LID (38.7 microgram/L) was significantly lower than that of healthy subjects (238.8 microgram/L) (P<0.0001). CONCLUSIONS: Urinary iodine analysis by ICP-MS showed good linearity, precision, accuracy, wide measuring range of detection, and lower LLOQ. This method will be very useful to evaluate the status of dietary iodine intake and the appropriateness of LID in thyroid cancer patients, thereby maximizing the effect of RAIT.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Espectrometria de Massas / Neoplasias da Glândula Tireoide / Reprodutibilidade dos Testes / Dieta / Limite de Detecção / Iodo Tipo de estudo: Guideline Limite: Adult / Female / Humans / Male Idioma: Ko Revista: The Korean Journal of Laboratory Medicine Ano de publicação: 2010 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Espectrometria de Massas / Neoplasias da Glândula Tireoide / Reprodutibilidade dos Testes / Dieta / Limite de Detecção / Iodo Tipo de estudo: Guideline Limite: Adult / Female / Humans / Male Idioma: Ko Revista: The Korean Journal of Laboratory Medicine Ano de publicação: 2010 Tipo de documento: Article