An HPLC-MS/MS method for the determination of trans-ferulic acid in human plasma / 药学学报
Acta Pharmaceutica Sinica ; (12): 450-2016.
Artigo em Chinês | WPRIM | ID: wpr-779191
ABSTRACT
In this study, we developed a sensitive and rapid HPLC-MS/MS method for the determination of trans-ferulic acid (trans-FA) in plasma samples, and investigated the pharmacokinetics characteristics in healthy volunteers. The plasma samples were extracted with acetic ether, and then separated on a Hedera ODS-2 column with a mobile phase of methanol and 5 mmol·L-1 ammonium acetate buffer solution containing 0.05% acetic acid (3466) at a flow rate of 0.4 mL·min-1. Electrospray ionization source was applied and operated in the positive ion mode using MRM. The method exhibited a good linearity over the concentration range of 0.1-5 ng·mL-1 (r ≥ 0.9992). The values on both the occasions (intra-and inter-day) were all within 9.2%, and the accuracy was 95.4%-111.4%. No matrix effect and carry-over effect were observed. Trans-FA was stable in human plasma under different storage conditions. The developed HPLC-MS/MS method is rapid, sensitive, accurate, and reproducible, and suitable for the pharmacokinetic study of trans-FA in healthy Chinese volunteers.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Acta Pharmaceutica Sinica Ano de publicação: 2016 Tipo de documento: Artigo