ABSTRACT
Objective To investigate the applicafion value of a simple stereotaxic technology in open biopsy of breast calcification with wire localization guided by X-ray.Methods 36 lesions in 30 cases with calcifications on mammography underwent X-ray guided simple wire stereotaxic localization open biopsy.Results 36 lesions in 30 cases were removed completely after wire localization,among which 24 cases were removed completely by one time,accounting for 80% (24/30)of the total,and 6 cases were removed completely by two times,accounting for 20% (6/30)of the total.No case were removed without calcification or removed completely by more than three times.Conclusion The simple stereotaxic technology in open biopsy of breast calcification with wire localization guided by X-ray is easy to learn and safe to do,which is suitable for promotion at the grassroots hospital.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Endocrine Surgery Ano de publicação: 2019 Tipo de documento: Artigo