Your browser doesn't support javascript.
loading
Biomechanical Properties of Porous Titanium Cages for Different Lumbar Interbody Fusion Surgeries / 医用生物力学
Journal of Medical Biomechanics ; (6): E243-E250, 2019.
Article em Zh | WPRIM | ID: wpr-802449
Biblioteca responsável: WPRO
ABSTRACT
Objective To study the biomechanical properties of porous titanium cages used for different lumbar interbody fusion surgeries. Methods The three-dimensional (3D) finite element model of the lumbar spine was constructed, and mechanical parameters of porous materials were obtained by mechanical test. The biomechanical properties of porous titanium cages in anterior lumbar interbody fusion (ALIF), posterior lumbar interbody fusion (PLIF), transforaminal lumbar interbody fusion (TLIF), direct lateral interbody fusion (DLIF) were compared. Results After lumbar interbody surgery, the predicted range of motion (ROM) and the maximum stress in cage of DLIF model and ALIF model were substantially lower than those of PLIF model and TLIF model. The maximum stress in endplate of DLIF model, ALIF model and TLIF model were obviously lower than that of PLIF model. Conclusions DLIF with the porous cage showed advantages in biomechanical properties, which was simple to operate and suitable for minimally invasive surgery in clinical practice. DLIF performed the superior comprehensive properties.
Palavras-chave
Texto completo: 1 Índice: WPRIM Tipo de estudo: Prognostic_studies Idioma: Zh Revista: Journal of Medical Biomechanics Ano de publicação: 2019 Tipo de documento: Article