Determination of tributyl phosphate in the air of workplace by gas chromatography / 中华劳动卫生职业病杂志
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 618-621, 2017.
Artigo em Chinês | WPRIM | ID: wpr-809090
ABSTRACT
Objective@#To establish a practical method forsampling and detectingtributyl phosphate intheworkplace.@*Methods@#The samples were extracted by glass fiber membrane, eluted with ether, separated by gas chromatography, and detected by flame photometric detector.@*Results@#There were good linear relationship in the minimum detection concentration was 7.2-720.0 μg/ml, and the correlation coefficient was 0.999 92. The detection limit was 0.86 μg/ml, and the minimum detection concentration was 0.14 mg/m3 (sample volume was 30 L) . Recovery rates were 99.8%-100.2%. The with-in relative standard deviations were 4.0%-5.4% and the between relative standard deviations were 2.0%-5.5%, and average samplingefficiency was about 99.1%-100.0%.@*Conclusion@#This method conforms with the requirements of "Standardization of Methods for Determination of Toxic Substance in Workplace" . Tributyl phosphate in air could be determined accurately using this method.