Clinical evaluation of retention strength of two different adhesive systems on glass fiber-reinforced posts / 口腔疾病防治
Journal of Prevention and Treatment for Stomatological Diseases
; (12): 515-518, 2017.
Article
em Zh
| WPRIM
| ID: wpr-822210
Biblioteca responsável:
WPRO
ABSTRACT
Objective@# To evaluate the clinical effect of two different resin cements on the glass fiber-reinforced posts.@*Methods @# One hundred and thirty-six teeth were randomly divided into two groups, with sixty-eight in each. Group A used Multilink N self-etch system and group B used RelyX Unicem self-adhesive system to bond fiber posts. Follow-up examinations took place at 6, 12 and 24 months after the placement. @*Results @#The success ratios of two groups were all 97% above and there was no significant difference between two groups (P > 0.05). @*Conclusion@#Multilink N self-etch system and RelyX Unicem self-adhesive system all have good effect on glass fiber-reinforced posts bonding.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Journal of Prevention and Treatment for Stomatological Diseases
Ano de publicação:
2017
Tipo de documento:
Article