Your browser doesn't support javascript.
loading
Effect of Monochromatic Energy Image Synthesized from Dual-layer Detector Spectral CT on Imaging of Inferior Vena Cava / 中国医学科学院学报
Acta Academiae Medicinae Sinicae ; (6): 359-363, 2020.
Artigo em Chinês | WPRIM | ID: wpr-826356
ABSTRACT
To evaluate the effect of monochromatic energy image on inferior vena cava imaging quality on dual-layer detector spectral CT. Totally 39 patients who were clinically suspected of abdominal disease and referred to perform contrast-enhanced computed tomography(CT)were prospectively enrolled and underwent abdominal examination using a single-source,dual-detector spectral CT.The delayed phase scan was performed 3 minutes after injection of 60 ml of iopamidol(320 mg/ml)at a rate of 3 ml/s.The raw images were reconstructed to obtain conventional mixed energy images and spectral based images(SBI).The 40,50,60,and 70 keV single energy images were obtained.The CT value,noise,and signal-to-noise(SNR)of inferior vena cava and the contrast-to-noise(CNR)of inferior vena cava relative to psoas major on conventional mixed energy images and the 40,50,60,70 keV single energy images were measured.The SNRs and CNRs on monoenergetic 40-70 keV images were compared with polychromatic 120 kVp images.ANOVA was used to compare the CT value,noise,SNR,and CNR among these five groups.The optimal monoenergetic image set was chosen. The differences in CT value,noise,SNR,CNR of inferior vena cava were statistically significant among five groups(all <0.05).The SNR and CNR in 40 keV group and 50 keV group were significantly higher than those in other groups(all <0.05).The SNR of 40 keV group was significantly higher than that of 50 keV group(=0.002).The CNR of 40 keV group was not statistical different compared with that of 50 keV group(=0.630). 40 keV is the optimal monoenergetic energy level for the inferior vena cava on dual-layer detector spectral CT and may be valuable for the diagnosis of inferior vena cava disease.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Veia Cava Inferior / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Abdome / Razão Sinal-Ruído Limite: Humanos Idioma: Chinês Revista: Acta Academiae Medicinae Sinicae Ano de publicação: 2020 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Veia Cava Inferior / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Abdome / Razão Sinal-Ruído Limite: Humanos Idioma: Chinês Revista: Acta Academiae Medicinae Sinicae Ano de publicação: 2020 Tipo de documento: Artigo