ABSTRACT
To explore a method for calculating water equivalent diameter () based on localizer CT images for calculation of the size specific dose estimates (SSDE).GE Revolution CT and LightSpeed VCT were used to scan CT dose index phantoms 16 cm and 32 cm in diameter at the tube voltages of 80, 100 and 120 kV to obtain the axial image and anteroposterior localizer radiograph. According to the definition of CT Hounsfield unit, the axial images were used to calculate the conversion factors that convert the phantom thickness to water equivalent thickness. The gray value of the localizer radiograph and the water equivalent thickness were calibrated with a linear equation, and the parameters of the calibration were used to calculate the water equivalent thickness. The method was verified using 2 CT dose index phantoms and in 22 patients undergoing chest and abdominal CT examination.Comparison of the water equivalent diameter () based on the localizer radiograph and axial image of the 2 phantoms showed that the percentage difference between from the axial images and from the localizer radiograph was below 3%. The trend of variations with location in the two methods was sonsistent. The difference in in intermediate region of interest between the axial image and the localizer radiograph from the 22 patients was below 6.6%. With the mean in the ROI, the maximum percentage difference was 7.5%.Calibration of the gray value of the localizer radiograph and the water equivalent thickness using the axial image and localizer radiograph of CT dose index phantoms allows quick calculation of the SSDE based on the parameters of calibration.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Doses de Radiação / Calibragem / Água / Tomografia Computadorizada por Raios X / Imagens de Fantasmas Limite: Humanos Idioma: Chinês Revista: Journal of Southern Medical University Ano de publicação: 2020 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Doses de Radiação / Calibragem / Água / Tomografia Computadorizada por Raios X / Imagens de Fantasmas Limite: Humanos Idioma: Chinês Revista: Journal of Southern Medical University Ano de publicação: 2020 Tipo de documento: Artigo